Techno Blender
Digitally Yours.

Diamond Quantum Sensor Measures Currents in the Heart at Millimeter Resolution

0 51


Many heart problems, including tachycardia and fibrillation, mainly originate from imperfections in the way electric currents propagate through the heart. Unfortunately, it is difficult for doctors to study these imperfections. This is because measuring these currents involves highly invasive procedures and exposure to X-ray radiation.

Luckily, there are other options. For example, magnetocardiography (MCG) is a promising alternative approach to measuring heart currents indirectly. The technique involves sensing minute changes in the magnetic field near the heart caused by cardiac currents. This can be done in a completely contactless manner. To this end, various types of quantum sensors suitable for this purpose have been developed. However, their spatial resolution is limited to centimeter scales, which is not good enough to detect cardiac currents that propagate at millimeter scales. Furthermore, each of these sensors has a fair share of its practical limitations, such as size and operating temperature.

In a new study published today (August 23, 2022) in Communications Physics, a team of scientists developed a novel setup to perform MCG at higher resolutions. Their approach is based on a diamond quantum sensor comprising nitrogen vacancies, which act as special magnetic “centers” that are sensitive to the weak magnetic fields produced by heart currents. The researchers were led by Associate Professor Takayuki Iwasaki of Tokyo Institute of Technology (Tokyo Tech), Japan.

But how does one observe the state of these centers to extract information about the cardiac currents? It turns out that the sensor is also fluorescent, which means that it easily absorbs light at specific frequencies and then re-emits them at different frequencies. Most importantly, the intensity of the light re-emitted at the nitrogen vacancies changes depending on the intensity and direction of the external magnetic field.

The researchers created an MCG setup using a 532 nm (green) laser to excite the diamond sensor and a photodiode to capture the re-emitted photons (light particles). They also developed mathematical models to accurately map these captured photons with the corresponding magnetic fields and, in turn, with the cardiac currents responsible for them.

With an unprecedented spatial resolution of 5.1 mm (0.20 inches), the proposed system could create detailed two-dimensional maps of the cardiac currents measured in the hearts of laboratory rats. In addition, unlike other well-established MCG sensors that require cryogenic temperatures, the diamond sensor could operate at room temperature. This enabled the researchers to position their sensor extremely close to the heart tissue, which amplified the measured signals. “The advantages of our contactless sensor combined with our current models will allow for more precise observations of cardiac imperfections using small mammalian model animals,” highlights Dr. Iwasaki.

Overall, the MCG setup developed in this study appears to be a promising tool for understanding many heart problems as well as other bodily processes involving electric currents. In this regard, Dr. Iwasaki remarks: “Our technique will enable the study of the origin and progression of various cardiac arrhythmias, as well as other biological current-driven phenomena.”

Let us hope the research team’s efforts will help deepen our knowledge about heart diseases, contributing to saving lives through modern medicine.

Reference: “Millimetre-scale magnetocardiography of living rats with thoracotomy” 23 August 2022, Communications Physics.
DOI: 10.1038/s42005-022-00978-0

Funding: The Ministry of Education, Culture, Sports, Science and Technology, Japan Science and Technology Agency




Quantum Sensor Images Cardiac Currents at Millimeter Resolution

Many heart problems, including tachycardia and fibrillation, mainly originate from imperfections in the way electric currents propagate through the heart. Unfortunately, it is difficult for doctors to study these imperfections. This is because measuring these currents involves highly invasive procedures and exposure to X-ray radiation.

Luckily, there are other options. For example, magnetocardiography (MCG) is a promising alternative approach to measuring heart currents indirectly. The technique involves sensing minute changes in the magnetic field near the heart caused by cardiac currents. This can be done in a completely contactless manner. To this end, various types of quantum sensors suitable for this purpose have been developed. However, their spatial resolution is limited to centimeter scales, which is not good enough to detect cardiac currents that propagate at millimeter scales. Furthermore, each of these sensors has a fair share of its practical limitations, such as size and operating temperature.

In a new study published today (August 23, 2022) in Communications Physics, a team of scientists developed a novel setup to perform MCG at higher resolutions. Their approach is based on a diamond quantum sensor comprising nitrogen vacancies, which act as special magnetic “centers” that are sensitive to the weak magnetic fields produced by heart currents. The researchers were led by Associate Professor Takayuki Iwasaki of Tokyo Institute of Technology (Tokyo Tech), Japan.

But how does one observe the state of these centers to extract information about the cardiac currents? It turns out that the sensor is also fluorescent, which means that it easily absorbs light at specific frequencies and then re-emits them at different frequencies. Most importantly, the intensity of the light re-emitted at the nitrogen vacancies changes depending on the intensity and direction of the external magnetic field.

The researchers created an MCG setup using a 532 nm (green) laser to excite the diamond sensor and a photodiode to capture the re-emitted photons (light particles). They also developed mathematical models to accurately map these captured photons with the corresponding magnetic fields and, in turn, with the cardiac currents responsible for them.

With an unprecedented spatial resolution of 5.1 mm (0.20 inches), the proposed system could create detailed two-dimensional maps of the cardiac currents measured in the hearts of laboratory rats. In addition, unlike other well-established MCG sensors that require cryogenic temperatures, the diamond sensor could operate at room temperature. This enabled the researchers to position their sensor extremely close to the heart tissue, which amplified the measured signals. “The advantages of our contactless sensor combined with our current models will allow for more precise observations of cardiac imperfections using small mammalian model animals,” highlights Dr. Iwasaki.

Overall, the MCG setup developed in this study appears to be a promising tool for understanding many heart problems as well as other bodily processes involving electric currents. In this regard, Dr. Iwasaki remarks: “Our technique will enable the study of the origin and progression of various cardiac arrhythmias, as well as other biological current-driven phenomena.”

Let us hope the research team’s efforts will help deepen our knowledge about heart diseases, contributing to saving lives through modern medicine.

Reference: “Millimetre-scale magnetocardiography of living rats with thoracotomy” 23 August 2022, Communications Physics.
DOI: 10.1038/s42005-022-00978-0

Funding: The Ministry of Education, Culture, Sports, Science and Technology, Japan Science and Technology Agency

FOLLOW US ON GOOGLE NEWS

Read original article here

Denial of responsibility! Techno Blender is an automatic aggregator of the all world’s media. In each content, the hyperlink to the primary source is specified. All trademarks belong to their rightful owners, all materials to their authors. If you are the owner of the content and do not want us to publish your materials, please contact us by email – [email protected]. The content will be deleted within 24 hours.

Leave a comment